CS604LGT2DH13 natural gas filter element is a separation and purification equipment element for natural gas gathering and transportation pipelines and gas gathering stations, compressor stations, sub-transportation stations, pigging stations, terminal stations and various application fields.
1. Product Overview
The CS604LGT2DH13 natural gas filter element is a specialized separation and purification component designed for natural
gas gathering and transportation pipelines, gas gathering stations, compressor stations, sub-transmission stations, pigging
stations, terminal stations, and various other application fields. Its primary function is to remove dirt, solid particles, pipe scale,
and other contaminants from natural gas streams, ensuring safe operation of gas transmission equipment and meeting the
quality requirements of pipeline transportation and end-users.
Manufactured with high-quality materials and precision engineering, this filter element delivers reliable performance under
demanding pipeline conditions. It is designed for direct interchangeability with original specifications—same dimensions,
sealing interfaces, and flow characteristics—enabling drop-in installation without housing modifications.
Please note: Aite is an independent manufacturer and not an authorized distributor of the original brand. Our replacement
elements meet or exceed original performance specifications at a competitive price point.
2. Technical Specifications
Parameter Specification
Model Number CS604LGT2DH13
Filtration Precision 5 μm (absolute)
Filtration Efficiency ≥ 99.90%
Operating Temperature Range –10°C ~ +50°C
Maximum Working Pressure 6.4 MPa (64 bar)
Filter Media High-performance synthetic fiber / coalescing media
Structural Design Pleated for maximum surface area
Flow Direction Outside-in (typical)
Seal Material NBR / FKM (optional based on gas composition)
All geometric dimensions—outer diameter, inner diameter, length, and thread—are verified to ensure 100% interchangeability
with original housings.
3. Key Features and Advantages
Feature Benefit
High filtration efficiency ≥ 99.90% efficiency at 5 μm removes solid particles, rust, pipe scale, and other contaminants,
protecting downstream equipment from damage.
High-quality materials Premium media and structural components ensure mature technology, consistent performance,
and long service life.
Fine workmanship Precision-manufactured with flat mesh surface, uniform pore distribution, firm structure, and excellent
dimensional stability.
Large filtration area Pleated design maximizes effective filtration surface, allowing extended operation between replacements
and reducing maintenance frequency.
Long service life Robust construction and high dirt-holding capacity deliver extended operational life, lowering total cost of
ownership.
Customization support As a source manufacturer, we can produce tailored products based on specific working conditions,
pressure requirements, and gas compositions.
Cost-effective alternative 40–60% savings over genuine parts, with equivalent or superior performance.
Complete documentation Material certificates and performance test reports included with every shipment.
4. Application Fields
The CS604LGT2DH13 natural gas filter element is widely used across the natural gas industry:
Application Area Specific Installations
Gathering Stations Removal of contaminants from raw natural gas at wellhead collection points
Compressor Stations Protection of compressor systems from particle ingress before compression
Sub-Transmission Stations Filtration of natural gas for distribution to regional networks
Pigging Stations Capture of debris and scale dislodged during pipeline pigging operations
Terminal Stations Final filtration before delivery to industrial, commercial, or residential users
Gas Turbine Protection Pre-filtration for gas turbine fuel gas systems
City Gate Stations Filtration at city gas distribution entry points
Industrial Gas Processing Filtration for natural gas processing plants and chemical feedstocks
Our filter elements are compatible with dry natural gas, wet natural gas, and associated gas streams with various contaminant
loads and compositions.
5. Selection & Operation Guidelines
5.1 Filtration Efficiency & Precision
With 5 μm absolute filtration at ≥ 99.90% efficiency, the CS604LGT2DH13 effectively captures solid particles including:
· Pipe scale and rust fragments from pipeline internal surfaces
· Sand, dust, and formation fines from gas production
· Welding slag and debris from pipeline construction
· Iron sulfide particles and other corrosive by-products
This level of cleanliness protects compressors, turbines, valves, regulators, and metering equipment from abrasive wear and
operational failure.
5.2 Replacement Indication
Monitor the differential pressure across the filter element. Replace when DP reaches the manufacturer's recommended
limit—typically 0.1–0.15 MPa above initial clean pressure drop for natural gas applications. Actual replacement intervals depend
on gas quality, pipeline age, and upstream contamination levels.
5.3 Storage Conditions
Store unused elements in original packaging in a cool, dry, dust-free environment. Avoid direct sunlight, extreme temperatures,
and moisture. Recommended storage temperature: 0°C ~ 40°C with relative humidity <70%.
5.4 Disposal
Used elements may contain hydrocarbon residues, condensates, or hazardous contaminants. Follow local environmental
regulations for disposal—drain any liquid and dispose as industrial waste or through authorized recycling channels.
Frequently Asked Questions (FAQ)
Q1: What is the recommended replacement interval for the CS604LGT2DH13 natural gas filter element?
A: The interval depends on gas quality, pipeline conditions, and upstream contamination levels. Monitor the differential pressure
gauge—replace when DP reaches 0.1–0.15 MPa above initial clean pressure drop. Under typical operating conditions,
replacement every 6–12 months or based on DP trend is recommended.
Q2: Can this filter element be cleaned and reused?
A: No. This element is designed for single-use only. Cleaning may damage the media, reduce filtration efficiency, and cause
media migration—leading to particle breakthrough and downstream equipment damage. Always replace with a new element.
Q3: How do I confirm compatibility with my existing filter housing?
A: Check the model number on your existing element and compare dimensions (outer diameter, inner diameter, length),
seal type, and flow direction. Our CS604LGT2DH13 follows original specifications for 1:1 interchangeability—no housing
modifications required. Our technical team can assist with cross-referencing.
Q4: What is the difference between your CS604LGT2DH13 and the original brand element?
A: Our element is manufactured using equivalent high-quality synthetic fiber/coalescing media and premium structural
components, meeting or exceeding original performance specifications—including ≥99.90% efficiency at 5 μm. It offers
reliable filtration performance at 40–60% cost savings with faster delivery times.
Q5: What does "filtration efficiency ≥ 99.90%" mean in practice?
A: This means that at the rated 5 μm particle size, the filter captures at least 99.90% of particles. In other words, fewer than 1
out of 1,000 particles at 5 μm or larger pass through the element. This provides excellent protection for compressors, turbines,
and other sensitive gas equipment.
Q6: Can this filter element handle natural gas with high liquid loading (wet gas)?
A: The CS604LGT2DH13 is designed primarily for solid particle removal in natural gas streams. For applications with high liquid
content (water, hydrocarbons, or glycol carryover), we offer coalescing media variants for liquid separation. Please consult our
technical team for specific wet-gas recommendations.
Q7: What is the operating pressure limit for this element?
A: The CS604LGT2DH13 is rated for maximum working pressure of 6.4 MPa (64 bar). For systems with higher operating pressures,
we offer custom-engineered elements with enhanced structural strength. Please specify your system pressure when ordering.
Q8: Why is the temperature range limited to –10°C to +50°C?
A: This temperature range covers typical natural gas pipeline operating conditions. For extreme low-temperature or
high-temperature applications (such as Arctic pipelines or downstream processing facilities), we offer special media and seal
materials—contact our technical team for customized options.
Q9: Is this element suitable for both onshore and offshore natural gas applications?
A: Yes. The CS604LGT2DH13 is suitable for both onshore and offshore installations, including offshore platforms and FPSO
facilities. For offshore applications, we recommend specifying corrosion-resistant materials and appropriate seal selection for
the gas composition.
Q10: Can I use this element for gases other than natural gas?
A: The CS604LGT2DH13 is optimized for natural gas streams. For other gases such as nitrogen, CO₂, hydrogen, or biogas,
please consult our technical team—different media and material selections may be required based on chemical compatibility
and operating conditions.
Q11: Can you supply test certificates and documentation for export?
A: Yes. Every shipment includes material certificates, performance test reports, and factory inspection documents. Upon request,
we can provide third-party inspection reports (additional cost applies) to meet import requirements for various countries.
Q12: Do you keep the CS604LGT2DH13 in stock?
A: Yes. This is one of our popular natural gas filter models and is generally well-stocked. Trial orders (1–10 pcs) ship within 3–7
working days; bulk orders (500+ pcs) within 15 working days. Expedited shipping is available for urgent requirements.
Q13: Can you customize this filter element for my specific working conditions?
A: Yes. As a source manufacturer, we support full customization—including filtration precision, media type, dimensions,
seal materials, end-cap designs, and pressure ratings. Please provide your operating conditions and original sample/drawing,
and we will engineer a tailored solution.
Q14: What happens if the filter element becomes clogged?
A: A clogged element increases differential pressure, which may bypass the element (if a bypass valve is installed), allowing
unfiltered gas to pass through and risk downstream equipment damage. Without a bypass, high DP may cause element collapse.
Regular DP monitoring and timely replacement are essential.
Q15: Do you provide technical support for installation or troubleshooting?
A: Yes. Our in-house engineers have extensive experience in natural gas filtration. We provide free dimensional drawings,
installation guides, and remote video troubleshooting. For large projects, on-site commissioning support can be arranged
(subject to travel conditions).
Conclusion
The CS604LGT2DH13 natural gas filter element is a reliable, high-performance filtration solution designed for natural gas
gathering and transportation pipelines, compressor stations, and terminal facilities. With 5 μm precision, ≥99.90% efficiency,
6.4 MPa pressure rating, and high-quality construction, it effectively removes dirt, pipe scale, and contaminants to ensure safe
gas transmission and protect downstream equipment. Backed by fast delivery, customization capabilities, complete
documentation, and competitive pricing, this replacement element offers outstanding value for natural gas operators, pipeline
companies, and EPC contractors.
For cross-reference charts, technical datasheets, or a customized quotation, please contact our sales engineering team today.
We keep your gas transmission systems running—safely, reliably, and cost-effectively.




CS604LGT2DH13 – High-Efficiency Natural Gas Filter Element for Pipeline & Station Applications
Similar ProductsVIEW MORE >